Oil based industrial paint
-
DB-1A Acrylic Metal Baking Paint Series
-
DB-2B Polyurethane Two-Component Paint Series
-
DB-3C Acrylic Plastic Paint Series
-
DB-4D Alkyd Antirust Paint Series
-
DB-7G Epoxy Anti-rust And Anti-corrosion Primer
-
DB-7G Epoxy Anti-Rust And Anti-Corrosion Paint Series
-
DB-7G High-temperature Anticorrosive Coating Is resistant To 300 Degrees
-
DB-8H Fluorocarbon Paint Series
-
DB-9K Rubber Paint Series
-
DB-11M High Temperature Paint Series
-
DB-12N Floor Paint Series
-
DB-16T Thermal Insulation Coating Series
-
DB-17 Polyurea Waterproof Coating Series
-
DB-18V Oil-Based Exterior Wall Paint Series
-
Polyamide Side Lacquer
-
Epoxy Cloud Iron Intermediate Paint
-
Epoxy Rich In Zinc Primer
-
Chlorinated Rubber Anti-corrosion Coating Material
-
Highly Chlorinated Polyethylene Anti-corrosion Coating
-
Water-resistant Coatings
DB-4D Alkyd Antirust Paint Series
1. Product parameters
Product: Alkyd Antirust Paint |
Brand: DuPont |
Color: gray, iron red, etc. |
Ingredients: Alkyd resin, Anti-rust pigment |
Coating: Anti-rust paint |
Performance: Anti-rust |
Substrate: Steel |
Packing: 10-20kg/drum |
Storage: Store in a dry and cool place, away from fire |
2. Composition
Alkyd antirust paint is referred to as antirust paint, which is composed of alkyd resin, antirust pigment and additives.
3. Common colors
The color of the paint is relatively fixed. According to the raw materials, gray, iron red, etc. can be produced, and other colors can be adjusted.
4. Product performance
Alkyd anti-rust paint has good anti-rust properties. It is mainly used in the protection and anti-rust of steel surface. The construction process is simple. It has been widely used as industrial paint and civil paint.
Alkyd anti-rust paint is a widely used anti-rust paint. It has a remarkable anti-rust effect on steel and machinery. The price is reasonable and meets the needs of the public.
5. Technical description
Serial number |
Test items |
Test value |
1 |
Paint Film Color and Appearance |
The paint film is smooth and flat |
2 |
Flash point,℃ |
36.5 |
3 |
Drying time,h |
Surface dry≤4h Hard work≤24h |
4 |
Hardness |
HB |
5 |
Outflow time,s |
≥45 |
6 |
Fineness,um |
≤40 |
7 |
Hiding power,g/m2 |
≤80 |
8 |
Impact resistance,cm |
50 |
9 |
Saltwater resistance(72h) |
No blistering, no rust, slight discoloration |
6. Application supporting
Alkyd anti-rust paint is used in many steel facilities, steel structures, mechanical equipment, engineering facilities, bridges, guardrails, etc. according to its excellent anti-rust function.
The paint can be topcoat with alkyd enamel, alkyd blend, acrylic, etc.
7.spraying process
1. Unpack the alkyd anti-rust paint, add an appropriate amount of alkyd thinner, stir well, mature and let stand for about 3 to 5 minutes.
2. The surface of the coated object is sandblasted and cleaned to reach Sa2.5 level, and the surface has a bright metallic color. There is no sand, oxide layer, rust, oil spots, etc. on the surface of the substrate.
3. The spray gun should maintain a right angle with the coating surface. The speed of the spray gun should be appropriate. If it is too fast, the paint will adhere less and the surface will be rough. If it is too slow, the paint will adhere more easily and sag.
4. The alkyd anti-rust paint is sprayed 1-2 times with an interval of 4 hours. After the construction is completed, it takes 24 hours to ensure that it is dry.
5. Use thinner to clean the residual paint in the spray gun, use a spray gun brush and solvent to clean the nozzle, and use a rag soaked in thinner to clean the outside of the gun body.
6. Spraying reference: The coating rate is two times of spraying, about 5 square meters per kilogram, and the thickness of the paint film is 25-30 microns for one time.
8. brushing process
1. There are many types of paint brushes, which are selected according to the structure and shape of the workpiece.
2. Mix paint and thinner, stir well and mature.
9. Precautions
1. The mixed paint must be used up within 6 hours.
2. Construction is not allowed in rainy, snowy and windy weather.
3. The construction environment temperature is above zero 5 ℃, and it is not suitable for construction in the temperature below zero and in winter.
4. The thinner mainly adjusts the workability and drying speed of the paint. The amount of thinner is different according to the construction conditions, temperature and paint type.
5. After the construction is completed, the workpiece should be left for more than 7 days to allow the paint to dry completely before it can be put into use.
10. Storage
1. Paints and thinners should be sealed and stored in a cool place, protected from fire, leakage, sun protection, high temperature, and away from fire sources.
2. The paint storage period is more than one year.
3. After the paint is opened, it should be fully stirred to prevent the pigment from sinking to the bottom and causing color difference.
4. If there are dust, particles, oil stains and other attachments on the surface of the workpiece, the appearance will be damaged, so it should be cleaned before spraying.
5. Due to different plastic substrates, it should be fully tested before spraying, so as not to affect the paint adhesion.
6. During construction, please do the relevant labor protection. The skin contact coating can be washed with washing powder and water. If you feel unwell, please seek medical help.